Fronius Selectiva 3.0 - External Start;Stop and Charging Lights; External Start;Stop Functionality and Spark Prevention; Connecting External Lamps for Charge Status Indication

Fronius Selectiva 3.0
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
mm (in.)
464 (18.27)
110 (4.33)
198 (7.8)
278 (10.94)
External start/
stop
The external start/stop option prevents spark formation at the charging plug if it
is disconnected during charging. Special contacts inside the charging plug re-
gister a disconnection. These contacts are leading in comparison to the main
contacts. An immediate charging stop is triggered. There is therefore no wear on
the main contacts and the level of safety against oxyhydrogen ignition is in-
creased.
Temperature-
controlled char-
ging
The temperature-controlled charging option always adjusts the charging voltage
according to the current temperature of the battery. This results in considerably
longer battery-life, especially where batteries are used in cold stores.
LED strip The LED strip acts as a status indicator and lights up in the same colours as the
display elements on the control panel. An LED strip including a diffuser is in-
stalled in the gap between the front wall and upper part of the housing.