EasyManua.ls Logo

Fronius Selectiva 3.0 - Additional Options: Brackets, LEDs, and Air Filters; Battery Cooling, Air Pump, and Bracket Installation; LED Strip, IP Protection, Air Filter, and Mobile Kit; Remote Control System Functionality

Fronius Selectiva 3.0
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Device-specific
data
Max. AC
current
Max. AC
power
Nominal
voltage
Max.
charging
current Weight
6)
2070 2 kW 12.1 A 2350 W 24 V 70 A 6.1 kg
(13.45 lb)
4020 2 kW 7.9 A 1530 W 48 V 20 A 5.8 kg
(12.79 lb)
4035 2 kW 11.9 A 2330 W 48 V 35 A 5.8 kg
(12.79 lb)
6)
With standard mains and charging leads
Selectiva 3 kW
Mains voltage
1)
~ 230 V, ± 15%
Grid frequency 50/60 Hz
Mains fuse protection
2)
max. 16 A
Minimum mains lead cross section 1.5 mm² (0.002325 in.²)
Protection class I (with ground conductor)
Max. permitted mains impedance Z
max
on
PCC
3)
None
Standby consumption
24 V devices
48 V devices
4.9 W
5.1 W
EMC device class B
Dimensions L x W x H 417 x 110 x 198 mm
(16.42 x 4.33 x 7.8 in.)
Degree of contamination 3
Degree of protection
4)
IP21
Overvoltage category II
Operating temperature
5)
-20°C to +40°C
(-4°F to 104°F)
Storage temperature -25°C to +80°C
(-13°F to 176°F)
Relative humidity maximum 85%
Maximum altitude above sea level 2000 m (6561 ft.)
Mark of conformity according to rating plate
Product standard EN62477-1
1)
The device is approved for operation on neutral-earthed networks.
2)
The thermal stress of the circuit breaker must not exceed 30,000 A
2
s.
The leakage current to earth is less than 3.5 mA.
3)
Interface to a 230/400 V and 50 Hz public grid.
4)
For indoor use only, do not expose to rain or snow.