Contact detection
-
ON
When Start Normal is ON, a battery is connected and the external start/stop
contact is not closed, error 16 is set.
When Stop Normal is ON, charging has started, the external start/stop con-
tact is open and the battery is not disconnected, error 16 is set.
-
OFF
Contact detection does not take place.
Refill Indicator
The refill indicator is a message that appears as soon as the battery needs top-
ping up with distilled water. The time at which refilling is deemed necessary can
be defined as follows:
Every nth week and weekday
-
e.g. top up with water every fortnight on a Friday
If set to "OFF", the refilling request does not have to be confirmed.
Option Section
Option Section 1
-
Setting options:
CAN1 (option box)
Cool Bat Guide Easy (Fronius variants only)
Option Section 2 (3 kW only)
-
Setting options:
CAN2 (option box)
AirPuls (EUW)
Status outputs (3 kW only)
-
Setting for external lamp (normal or RGB)
At mains failure restart charging
If this option is selected, the charging process is restarted automatically as soon
as the mains supply becomes available again after a disruption to the electrical
mains supply.
General settings Detailed explanation of the "general options" menu item in configuration mode.
47
EN