Technical data
Selectiva 2 kW
Mains voltage
1)
~ 230 V, ± 15%
Grid frequency 50/60 Hz
Mains fuse protection
2)
max. 16 A
Minimum mains lead cross section 1.5 mm² (0.002325 in.²)
Protection class I (with ground conductor)
Max. permitted mains impedance Z
max
on
PCC
3)
None
Standby usage 4.9 W
EMC device class B
Dimensions L x W x H 341 x 110 x 198 mm
(13.43 x 4.33 x 7.8 in.)
Degree of contamination 3
Degree of protection
4)
IP21
Overvoltage category II
Operating temperature
5)
-20°C to +40°C
(-4°F to 104°F)
Storage temperature -25°C to +80°C
(-13°F to 176°F)
Relative humidity maximum 85%
Maximum altitude above sea level 2000 m (6561 ft.)
Mark of conformity according to rating plate
Product standard EN62477-1
1)
The device is approved for operation on neutral-earthed networks.
2)
The thermal stress of the circuit breaker must not exceed 30,000 A
2
s.
The leakage current to earth is less than 3.5 mA.
3)
Interface to a 230/400 V and 50 Hz public grid.
4)
For indoor use only, do not expose to rain or snow.
5)
A high ambient temperature may result in power degradation (derating).
Device-specific
data
Max. AC
current
Max. AC
power
Nominal
voltage
Max.
charging
current Weight
6)
2040 2 kW 7.9 A 1540 W 24 V 40 A 5.8 kg
(12.79 lb)
2050 2 kW 9.9 A 1930 W 24 V 50 A 6.1 kg
(13.45 lb)
2060 2 kW 12.0 A 2330 W 24 V 60 A 6.1 kg
(13.45 lb)
61
EN

Table of Contents

Other manuals for Fronius Selectiva 3.0

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Selectiva 3.0 and is the answer not in the manual?

Fronius Selectiva 3.0 Specifications

General IconGeneral
BrandFronius
ModelSelectiva 3.0
CategoryBattery Charger
LanguageEnglish

Related product manuals