EFd | 81, EFd | 83
Fault in the wire feed system (overcurrent in wire-feed unit drive)
Arrange the hosepack in as straight a line as possible; check that there are
no kinks or dirt in the inner liner; check the contact pressure on the 4 roller
drive
Wire-feed unit motor is sticking or defective
Check the wire-feed unit motor or contact After-Sales Service
Cause:
Remedy:
Cause:
Remedy:
to0 | xxx
Note: xxx stands for a temperature value
Overtemperature in the primary circuit of the power source
Allow power source to cool down, check air filter and clean if necessary,
check that fan is on
Cause:
Remedy:
to1 | xxx
Note: xxx stands for a temperature value
Overtemperature on the booster located in the power source
Allow power source to cool down, check air filter and clean if necessary,
check that fan is on
Cause:
Remedy:
to2 | xxx
Note: xxx stands for a temperature value
Overtemperature in the secondary circuit of the power source
Allow power source to cool down, check that fan is on
Cause:
Remedy:
to3 | xxx
Remark: xxx stands for a temperature value
Overtemperature in the wire-feed unit motor
Allow wire-feed unit to cool down
Cause:
Remedy:
to4 | xxx
Remark: xxx stands for a temperature value
Overtemperature in welding torch
Allow welding torch to cool down
Cause:
Remedy:
to5 | xxx
Note: xxx stands for a temperature value
Overtemperature in cooling unit
Allow cooling unit to cool down, check that fan is on
Cause:
Remedy:
to6 | xxx
Note: xxx stands for a temperature value
Overtemperature at the transformer of the power source
Allow power source to cool down, check air filter and clean if necessary,
check that fan is on
Cause:
Remedy: