Troubleshooting
General The devices are equipped with an intelligent safety system. This means that to a large
extent it has been possible to dispense with melting-type fuses. Melting-type fuses there-
fore no longer need to be replaced. After a possible malfunction has been remedied, the
device is ready for use again.
Safety
WARNING!
Work that is carried out incorrectly may result in serious injury or damage to prop-
erty.
The activities described below must only be carried out by trained and qualified per-
sonnel.
Observe the safety rules in the power source Operating Instructions.
WARNING!
An electric shock can be fatal.
Before opening the unit
Turn the mains switch to the "O" position
Unplug the device from the mains
Put up an easy-to-understand warning sign to stop anybody inadvertently switching
it back on again
Using a suitable measuring device, check to make sure that electrically charged
components (e.g. capacitors) have discharged
WARNING!
Danger from inadequate ground conductor connection.
Possible serious injury and damage to property.
The housing screws provide a suitable ground conductor connection for earthing the
housing and must NOT be replaced by any other screws that do not provide a reli-
able ground conductor connection.
Fault diagnosis Make a note of the serial number and configuration of the device and contact our After-
Sales Service team with a detailed description of the error, if
- errors occur that are not listed below