EasyManua.ls Logo

Fronius TransSteel 2700c

Fronius TransSteel 2700c
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Care, maintenance and disposal
General Under normal operating conditions, the welding system requires only a minimum of care
and maintenance. However, it is vital to observe some important points to ensure the
welding system remains in a usable condition for many years.
Safety
WARNING!
An electric shock can be fatal.
Before opening the device
Turn the mains switch to the "O" position
Unplug the device from the mains
Ensure the device cannot be switched back on
Using a suitable measuring instrument, check to make sure that electrically charged
components (e.g. capacitors) have been discharged
WARNING!
Work that is carried out incorrectly can cause serious injury and damage.
The following activities must only be carried out by trained and qualified personnel.
All instructions in the section headed "Safety rules" must be observed.
At every start-up - Check mains plug, mains cable, welding torch, interconnecting hosepack and
ground earth connection for damage
- Check that the device has an all-round clearance of 0.5 m (1 ft. 8 in.) to ensure that
cooling air can flow in and out freely
NOTE!
The air inlets and outlets must never be covered, not even partially.
If necessary If a lot of dust has accumulated:
TSt 2700c
- Remove the fin element on the rear of the housing
- Detach the air filter located behind and clean
TSt 3500c
- Remove the air filter on the rear of the housing from the side and clean
Every 2 months
CAUTION!
Risk of damage.
The air filter must only be fitted when dry.
If required, clean air filter using dry compressed air or by washing it.