Factory setting: 10 (393.7)
bbc burn-back time correction -
Burn back effect due to wire withdrawal at end of welding
Unit: s
Setting range: Aut, 0 - 0.3
Factory setting: Aut
Ito Ignition time-out function - Length of wire that is fed before the safety cut-
out is triggered
Unit: mm (in.)
Setting range: Off, 5 - 100 (Off, 0.2 - 3.94)
Factory setting: OFF
NOTE!
The "Ignition time-out" function (ito) is a safety function.
The length of wire that is fed before the safety cut-out trips may differ from the preset
wire length, particularly when the wire is being fed at fast wire feed speeds.
The "Ignition time-out" function (ito) is explained in the "Special functions and options"
section.
SPt Spot time - spot / stitch welding time
Unit: s
Setting range: OFF, 0.1 - 5
Factory setting: OFF
SPb Spot break - stitch pause time
Unit: s
Setting range: OFF, 0.1 - 10 (in 0.1 s increments)
Factory setting: OFF
FAC Factory - reset power source to factory settings
Press and hold down one of the "Parameter selection" buttons for 2 s to restore
the factory settings
- when "PrG" appears on the digital display, the power source has been reset.
IMPORTANT! When the power source is reset, all personal settings in the Setup
menu are lost.
When the power source is reset, operating points that were saved using the
"Save" buttons are not deleted, but are retained in the memory. The functions in
the second level of the Setup menu (2nd) are also not deleted. Exception: Igni-
tion time-out function parameter (ito).
2nd Second level of the Setup menu (see "Setup menu - level 2")
Setup parameters
for MMA welding
IMPORTANT! If you reset the power source using the FAC factory setup parameter, the
hot-current time (Hti) and HotStart current (HCU) setup parameters are also reset.
HCU HotStart current
Unit: %
Setting range: 100 - 200
84