Factory setting: 2T (2-step)
FAC Reset power source to factory settings
Press and hold down one of the "Parameter selection" buttons for 2 s to restore
the factory settings
- when "PrG" appears on the digital display, the power source has been reset
IMPORTANT! When the power source is reset, all personal settings in the Setup
menu are lost.
Operating points that were saved using the "Save" buttons are retained when the
power source is reset. The functions in the second level of the Setup menu (2nd)
are also not deleted. Exception: Ignition time-out function parameter (ito).
2nd Second level of the Setup menu (see "Setup menu - level 2")
Setup parameters
for MIG/MAG
standard syner-
gic welding
"Min." and "max." are used for setting ranges that differ according to power source, weld-
ing program, etc.
GPr Gas pre-flow time
Unit: s
Setting range: 0 - 9.9
Factory setting: 0.1
GPo Gas post-flow time
Unit: s
Setting range: 0 - 9.9
Factory setting: 0.1
SL Slope
Unit: s
Setting range: 0 - 9.9
Factory setting: 0.1
I-S I (current) - Starting current
Unit: % (of welding current)
Setting range: 0 - 200
Factory setting: 100
I-E I (current) - End: Final current
Unit: % (of welding current)
Setting range: 0 - 200
Factory setting: 50
t-S t (time) - Starting - Starting current duration
Unit: s
Setting range: OFF, 0.1 - 9.9
Factory setting: OFF
t-E t (time) - End: Final current time
Unit: s
Setting range: OFF, 0.1 - 9.9
Factory setting: OFF
Fdi Feeder inching - feeder inching speed
Unit: m/min (ipm.)
Setting range: 1 - max. (39.37 - max.)
83
EN