Mains fuse 16 A slow-blow
Mains voltage (U
1
) 3 x 400 V
Max. effective primary current (I
1eff
) 6.6 A
Max. primary current (I
1max
) 12.5 A
Mains fuse 16 A slow-blow
Mains voltage (U
1
) 3 x 460 V
Max. effective primary current (I
1eff
) 5.8 A
Max. primary current (I
1max
) 10.8 A
Mains fuse 16 A slow-blow
Mains voltage tolerance -15 % /+ 15 %
Mains frequency 50 / 60 Hz
Max. permitted mains impedance Z
max
on PCC
1)
136 mOhm
Welding current range (I
2
) MIG/MAG 10 - 270 A
Welding current range (I
2
) Rod electrode 10 - 270 A
Welding current at
10 min / 40 °C (104 °F)
30 %
270 A
60 %
210 A
100 %
170 A
Output voltage range according to standard character-
istic (U
2
) MIG/MAG 14.5 - 34.9 V
Output voltage range according to standard character-
istic (U
2
) Stabelektrode 20.4 - 34.9 V
Open circuit voltage (U
0
peak / U
0
r.m.s) 41 V
Apparent power at 400 V AC 8.66 kVA
Protection class IP 23
Insulation class B
Overvoltage category III
Pollution level according to IEC60664 3
Safety symbols S, CE
Dimensions l x w x h 687 x 276 x 445 mm
27.1 x 10.9 x 17.5 in.
Weight 30 kg
66.1 lb.
Max. shielding gas pressure 7 bar
101.49 psi
Wire feed speed 1 - 25 m/min
40 - 980 ipm
Wire drive 4-roller drive
Wire diameter 0.8 - 1.6 mm
0.03 - 0.06 in.
108