Max. primary current (I
1max
) 22.3 A
Mains fuse protection 16 A slow-blow
Apparent power 5.13 kVA
Mains voltage (U
1
) 1 x 240 V
Max. effective primary current (I
1eff
) 15.0 A
Max. primary current (I
1max
) 23.9 A
Mains fuse protection 15 A slow-blow
Apparent power 5.74 kVA
Mains voltage (U
1
) 1 x 240 V
Max. effective primary current (I
1eff
) 18.1 A
Max. primary current (I
1max
) 2.9 A
Mains fuse protection 20 A slow-blow
Apparent power 5,98 kVA
Mains voltage (U
1
) 1 x 240 V
Max. effective primary current (I
1eff
) 18.1 A
Max. primary current (I
1max
) 28.1 A
Mains fuse protection 30 A slow-blow
Apparent power 6.74 kVA
Mains voltage tolerance -10 % /+ 15 %
Mains frequency 50 / 60 Hz
Max. permitted mains impedance Z
max
on PCC
1)
142 mOhm
Welding current range (I
2
)
MIG/MAG
Rod electrode
10 - 270 A
10 - 270 A
Welding current range (I
2
) in single-phase operation
MIG/MAG
Rod electrode
10 - 220 A
10 - 180 A
Welding current at 10 min / 40 °C (104 °F)
U
1
= 200 - 230 V:
U
1
= 380 - 460 V:
30 %
270 A
270 A
60 %
200 A
200 A
100 %
170 A
170 A
Welding current in single-phase operation at
10 min / 40 °C (104 °F)
U
1
= 230 V, Fuse 16 A
15 %
2)
180 A
100 %
145 A
Welding current in single-phase operation at
10 min / 40 °C (104 °F)
U
1
= 240 V, Fuse 15 A
8 %
2)
180 A
100 %
145 A
Welding current in single-phase operation at
10 min / 40 °C (104 °F)
U
1
= 240 V, Fuse 20 A
11 %
2)
200 A
100 %
160 A