Mains voltage (U
1
) 3 x 400 V
Max. effective primary current (I
1eff
) 14.5 A
Max. primary current (I
1max
) 23 A
Mains fuse 35 A slow-blow
Mains voltage (U
1
) 3 x 460 V
Max. effective primary current (I
1eff
) 12.7 A
Max. primary current (I
1max
) 20.1 A
Mains fuse 35 A slow-blow
Mains voltage tolerance -10 % /+ 15 %
Mains frequency 50 / 60 Hz
Cos phi (1) 0.99
Max. permitted mains impedance Z
max
at PCC
1)
77 mOhm
Recommended earth-leakage circuit breaker Type B
Welding current range (I
2
)
MIG/MAG
Rod electrode
10 - 350 A
10 - 350 A
Welding current at 10 min / 40 °C (104 °F) 40 %
350 A
60 %
300 A
100 %
250 A
Output voltage range according to standard character-
istic (U
2
)
MIG/MAG
Rod electrode
14.5 - 38.5 V
20,4 - 35,0 V
Open circuit voltage (U
0
peak / U
0
r.m.s) 60 V
Apparent power at 400 V AC 15.87 kVA
Degree of protection IP 23
Type of cooling AF
Insulation class B
Overvoltage category III
Pollution level according to IEC60664 3
Safety symbols S, CE, CSA
Dimensions l x w x h 747 x 300 x 497 mm
29.4 x 11.8 x 19.6 in.
Weight 36 kg
79.4 lb.
Max. shielding gas pressure 5 bar
72.52 psi
Coolant Original Fronius
Wire feed speed 1 - 25 m/min
40 - 980 ipm
Wire drive 4-roller drive
112