System expansions
For c ooling, protection ag ainst re, and in order to comply with EMC (electromagnetic
compatibility) regulations, you must ret the slot cover.
2
1
Slide the slot cov
er into the slot (1).
Sw ivel the retaining clamp back again until you feel it click into place (2).
Close the casin
g(see"
Closing the casing", Page 36).
If you have ins
talled or removed a PCI board, please check the relevant PCI
slot settings
in the BI OS Setup. If necessary, change the settings. Furth er
information
is provided in the PC I board documenta tion.
Installing and removing heat sinks
Removing t
he heat sink
The s hape and po sition of the heat sink are device-dependent.
Open the casing (see "
Opening the casing", Pa ge 35).
Disconn
ect the cable of the fan (FAN1) f rom the mainboard.
U ndo the screws on the heat sink.
Lift th
e heat sink out of the casing.
You c an now replace the processor.
Never operate the device without a heat sink! Before initial startup, install the heat
sink again in the same way as it was installed in the device before removal.