For the drive enclosure, the POWER LED on the power supply unit emits green lights and the fan revolves at
high speed for 30 seconds.
Drive enclosure
Controller enclosure
Power supply unit (PSU#1)Power supply unit (PSU#0)
POWER
LED
5.2.3 Powering On
Turn on the PC terminal and the ETERNUS DX.
Follow the procedure below to turn on the ETERNUS DX.
After turning the power on, it takes approximately three minutes for the ETERNUS DX to become READY
(i.e. the READY LED (
) turns on). If an error is detected in a component during the initial power-on
diagnostics, it may take a longer time (up to ten minutes) for the ETERNUS DX to be in a READY state.
After power-off, wait for about one minute before turning power on again.
1 Press the Power switch of the controller enclosure.
Power switch
The POWER LED ( ) is turned on.