2 Connect the controller enclosure to the drive enclosure.
(1) Connect Controller 0 first.
Connect the DI (OUT) port of Controller 0 (CM#0) in the controller enclosure to the DI (IN) port of
I/O module 0 (IOM#0) in the drive enclosure with the mini SAS HD cable between enclosures.
Controller enclosure
Drive enclosure
(2) When two controllers are installed, connect Controller 1 next.
Connect the DI (OUT) port of Controller 1 (CM#1) in the controller enclosure to the DI (IN) port of
I/O module 1 (IOM#1) in the drive enclosure with the mini SAS HD cable between enclosures.
Controller enclosure
Drive enclosure
4.3 Power Synchronized Unit Connection
When using a power synchronized unit for power control, connect the power synchronized unit to the ETER-
NUS DX.
Refer to "Configuration Guide (Power Synchronized Unit)" for details about power synchronized units, the pro-
cedure for connecting power synchronized units to the ETERNUS DX, and required settings.
4.4 Power Cord Connection
Connect the power cords to the ETERNUS DX.
Chapter 4 Connecting Cables
4.3 Power Synchronized Unit Connection
49
FUJITSU Storage ETERNUS DX60 S3 Disk storage system Configuration Guide (Basic)
Copyright 2014 FUJITSU LIMITED
P3AM-9002-01ENZ0