Maintaining Units Periodic Inspections
Page 42 MDE-3893P Encore® and Eclipse® Series Owner’s Manual · December 2011
When other
components are
serviced
Eclipse unit
fiberglass
Look for loose fiberglass skins, missing brackets,
and missing mounting hardware.
Note: If repair is required, call an ASC/CSC.
• Owner—Inspect
• ASC/CSC only—Repair
CAUTION
Do not attempt to make these repairs yourself. Doing so could
result in severe injury or death.
WARNING
Every six months
(annually for
Encore 550) or if
fuel inventory
discrepancies
exist.
Meter
Calibration
Have the unit meters checked for proper calibration
and corrected as required. High volume stations
may require more frequent calibration checks when
compared to the low volume stations.
• Owner—arranges for
service
• ASC/CSC—tests and
re-calibrates, if required
For Units with Ecometer
Yearly Ecometer
Calibration
Have the unit meters checked for proper calibration
and corrected as required. Ecometers with proper
air purging during installation will not generally vary
from initial calibration settings.
• Owner—arranges for
service
• ASC/CSC—tests and
re-calibrates, if required
For Units Equipped with DEF
Once a week,
especially during
cold weather
DEF Hose
Retriever and
Nozzle Door
Mechanism
Verify if the hose retrieves properly. Verify if the
nozzle door opens and closes properly. From a half-
way lifted position, the door must close completely
unassisted, after the nozzle has been placed back
into the nozzle holder.
CAUTION
During cold weather, a hose retriever that does not retract
properly or a nozzle door that does not self close properly may
cause freezing of the nozzle, hose, or other components. This
prevents DEF from being dispensed or may cause damage to
components that results in leaks.
CAUTION
• Owner— Inspect
• ASC— Repair
After a DEF spill
occurs
Dispenser and
surrounding
metallic
components
Flush the DEF spill with water and dry the area with
clean rags, especially areas that contain metallic
parts.
Note: Spilled DEF can be slippery and will corrode
metallic parts.
DEF is mildly corrosive. Handle with care. Wear eye protection
and rubber gloves during any cleanup activity.
CAUTION
Owner
Recommended
Frequency Components Recommended Maintenance
Who Performs the
Inspection/Repair

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu SCALEOVIEW S17-2 and is the answer not in the manual?

Fujitsu SCALEOVIEW S17-2 Specifications

General IconGeneral
BrandFujitsu
ModelSCALEOVIEW S17-2
CategoryMonitor
LanguageEnglish

Related product manuals