13. Connect the power connection cable (power cable or USB bus power cable)
to the power supply source (AC outlet or computer), and turn on the
ScanSnap.
14. Reset the pick roller count.
1. Click the ScanSnap Manager icon in the notification area located at the far right of
the taskbar and select [Check consumable status] from the "Right-Click Menu" (page 87).
→ The [ScanSnap Manager - Check consumable status] window appears.
2. Click the [Reset] button for [PICK ROLLER Count].
→ A confirmation window appears.
3. Click the [Yes] button.
→ [PICK ROLLER Count] is reset to 0.