FELCOM 12
G3-2
3. Necessary settings are as below. (DTE installed only one)
*System Date & Time YY-MM-DD
*Preferred NCS AUTO
*MES Operation Mode INMARSAT-C
*Nav port INT or EXT (Depend on installation)
INT: Internal GPS Board
EXT: External Equipment
*Active port DTE 1
*Message Output Port DTE1
*EGC Output Port DTE1
2.2 Updating a Distress Alert: [F8]
Press [F8] key, and [1] key. The display should look like below.
Necessary settings are as below
* LES ID
The default LED ID is a current NCS (Factory setting is 144, AOR-ENCS).
Press the [Enter] key to display the LES ID list. Select a suitable LES by the
[] key followed by the [Enter] key.
*Protocol
Set to “Maritime”.
*Nature
Set to “Unspecified”.