FS-75/2550
A2-4
Setting Default
System
Channel
Function
0 1 2 3 4
SSB GMDSS
9951
Scan Stop Signal
Level
SQ
Level
S : 1 to 10 S=3 S=3
9952 Scan Stop Time
While
receiving
1 – 99 sec 0 0
9953 Sweep Width 0.01 to 29999.99kHz 100k 100k
9954
Sweep Step
Frequency
0.01 to 29999.99kHz 1.00k 1.00k
9955 Squelch Operation Voice S-Level
Voice +
S-Level
Voice or
S-Level
3 3
9956 Squelch Level S : 0 to 10 S=5 S=5
9957
Note-9
Squelch Delay Time 500 to 4000m sec 1000ms 1000m
9958
Squelch Activating
Frequency
500 to 2000Hz 1000Hz 1000Hz
9959
Squelch Activation
frequency when
2-tone alarm
2182kHz is received
No
change
1300Hz
(Open)
0 0
9960
Check meter on
display
Individual
All
1 1
*9997
Note-10
Selection of output
power
150W
AT-1560
-15
250W
AT-5000
250W
AT-1560
-25
0 0
*9998
User CH Memory &
Power ADJ
Enable Disable
1 1
*9999 Password Enter Password:75 to access (*) mark channel
Conform the following system setting for GMDSS.
9904 (TLX Usage) 0:TX/RX GMDSS default
9905 (TLX RX band width) 1:Narrow SSB/GMDSS default
9906 (TX Delay Time) 10 m sec SSB/GMDSS default
9908 (AM Usage) 1:RX SSB/GMDSS default
9911 (EM on 2182kHz) 3:J3E FIX SSB/GMDSS default
9915 (TX Tune) 0:Enable SSB/GMDSS default
9917 (EM with TX key ON) 0:Auto
(No change)
SSB/GMDSS default
9997 (Selection of output power)
0:FS-75 2:FS-2550 (AT-1560-25 installed)
9928 (Priority setting) 1 (When DSC-60 is connected.)