7.4.4 Voltage Configuration
Scroll to VOLTAGE CONFIG” from “OUTPUT CONFIG” using the▲▼ keys and press ENTER.
Use the◄►keys to select uni-polar which is 0 to 5 volts (negative full scale is mapped to 0 VDC, zero
load is mapped to 2.5 VDC and plus full scale is mapped to +5V) or bipolar which is -5 VDC to 5 VDC
(negative full scale is mapped to -5 VDC, zero load is mapped to 0 VDC and plus full scale is mapped to
+5VDC).
A prompt will be shown to set this value as a default setting.
SELECT DESIRED
VOLTAGE CONFIG
USING , KEYS
[BI-POLAR]
ALARM RELAY1
ALARM RELAY2
VOLTAGE CONFIG
CURRENT VALUE
WOULD YOU LIKE
TO SAVE AS
DEFAULT?
<YES> <NO>