Table 5-2. OrPT Troubleshooting (Cont'd)
Fault Probable Cause Checks Corrective Action
OrPT displays "No communication" message (Continued)
OrCU problem Incorrect SiteOmat
setup
Verify that OrPT
parameters defined in
SiteOmat match the
values presented in OrPT
display at power-on
Set the OrPT bus and
parameters according to
OrPT values presented in
OrPT display at power-on
Incorrect OrCU
setup
Login into OrPT and
verify that all parameters
match OrCU setup
Login into OrPT and
change setup so it suits
OrCU setup
Islander PLUS Manual