2-6. CABLES INSERTION
2-6.1. General
This paragraph describes the requirements and procedures for the insertion of cables in the conduits.
NOTE
All devices in the system must be connected to the
same electric power phase.
NOTE
The type of cable needed vary in accordance with
the device it connects. The wire used must be
stranded and not a solid core. Select a cable
specification in accordance with local environment
conditions.
CAUTION
For supply connections, use wires suitable for at
least 90°C.
Signal wiring connected in this box must be rated at
least 300 V
2-6.2. Types of Cables
Table 2-2 lists the types of cable in use for the wiring of the Islander PLUS system.