Instructions for SL500DC/SL800DC
www.gatexpertstore.com
B. Operation Graphic Illustration
Note: After changing the opening direction, L1 and L2 will flicker together, it’s a
notice that reminding you to re-set the running travel for the gate. Before re-setting,
it’s extremely important to enter into manual control mode to confirm the polarities
of the limit switch stops are correct and well contacted to the magnetic limit switch.
Alarm Lamp Setting(L5)
This setting is to select the working mode of alarm lamp (blinker or steady on)
A. Operation Instruction:
1. Press and hold “PROG” button for 3 sec. to enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on.
2. Press “PROG” button again for 3 sec. to enter into advanced menu. L0 will flicker
twice, then L1 will be steady on.
3. Press “+” button four times to select alarm lamp working mode option. Indicator light
L5 will be steady on.
4. Press “SET” button once to enter into alarm lamp working mode setting. Indicator
L0 flicker once, L1
will be steady on
Press “PROG”
again for 3 sec.
L0 flicker twice, L1
will be steady on
Press “+” or “-” to set, LED
will show the setting value
L1-L5 will be on in
sequence then all
flicker once and off.