EasyManua.ls Logo

GE Multilin W650 - Page 53

GE Multilin W650
622 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GEK-113032A W650 Wind Generator Protection System 2-23
2 PRODUCT DESCRIPTION 2.4 TECHNICAL SPECIFICATIONS
2
Default Baud Rate 19200
Protocols available:
ModBus
®
RTU / DNP 3.0
Typical distance: 1200 m
Isolation: dc kV1
CAN PORT:
Rear port:
Fiber CAN port in models X, Y, Z and cable CAN port in models C and M for
rear board 1
Physical Layer: ISO11898, High speed
Baud rate: 125 / 500 kbaud
Fiber Type: Multimode glass F.O. port with ST connectors
Fiber Wave length: 1300 nm
Fiber type:
multimode 62.5/125 μm or 50/125 μm
Maximum recommended length 1km (fiber); 500m (cable)
Isolation: 2 kV
ETHERNET PORT:
Rear port: COM3
Type (depending on model):
Model B: 10/100BaseTX self-negotiable
Model C: 10/100BaseTX + 100Base FX
Model D: 10/100BaseTX + redundant 100BaseFX (Physical media redundancy)
Model E: Redundant 10/100BaseTX self-negotiable ports
10/100BaseTX RJ45 connector
100BaseFX ST connectors
Wave length: 1300 nm
Fiber type:
multimode 62.5/125 μm or 50/125 μm
Protocols available: ModBus® TCP/IP
DNP over TCP/IP and UDP/IP
IEC 61850
Http, ftp, tftp (allow the use of a standard Internet browser)
Typical distance: 1.65 km
Response time to ModBus commands: 10 ms Typical
Isolation: 2 kV
In Models C and D, the 10/100BaseTX port is selected by an internal switch (see 3.3.3)
Two witness LED’s for transmission and reception are included

Table of Contents