OptiCenter OC06 Operation
63
1.
2.
The selected mesh size remains active until the system is switched on
again.
Starting recovery after a color change (waste/spraqy)
In coating mode with powder recovery (spray), the recovery powder can
first be fed into the after filter and then into the OptiSpeeder after the set
time has elapsed in the event of increased quality requirements after a
color change.
Parameter 3442 is used to set an automatic change from coating without
recovery (waste) to coating with recovery (spray).
A pinch valve distributor is used to feed the recovery powder to the after
filter during the adjustable time period. After the time set in parameter
3442 has elapsed, the recovery powder is returned to the powder cycle.
Fig.
55
:
(See chapter "Parameter description" on page 54.)