OptiCenter maintenance
Maintenance schedule
The following components or modules are subject to a maintenance
schedule:
Component
Activity
Tool
Interval
1
Pneumatic parts, pinch valves
Check for unusual noises
1 x daily
2
Side panels, interior
Check for powder
residues and clean
Air guns
1 x daily
3
Ring injector
Clean
Thinner
1 x monthly
4
Fluid plate in OptiSpeeder
Visual function check
1 x annually
5
Pinch hoses in all pinch valves
NW15
Replace
1 x annually
6
Fluid plate level sensor
Replace
1 x annually
7
Filter element check valves
injectors
Replace
1 x annually
8
Hose lines and fittings
Check
1 x annually
9
All electrical screw and clamp
connections
Check if firmly fitted
1 x annually
10
Pinch hose in pinch valve
(OptiSpeeder emptying)
Replace
Every 2
years
The specified intervals are based on operation of 8 hours per day.
The service life of the components depends heavily on the service
duration, the powder quality and the quality of the air supply.
Check for unusual noises
During operation of the machine pay attention to unusual noises. Stop the
machine immediately if an unusual noise can be heard. Check the
components at the noise source.
If no clear cause can be found, contact Gema customer service.
Wearing parts
Wearing parts replaced during maintenance can be individually
purchased (refer to spare parts list).