Rev. 00 04/19
OptiCenter OC06 Maintenance / Repairs
71
Cleaning
WARNING
Cleaning with compressed air!
Eye injury and bodily injury from compressed air and flying parts.
Wear eye protection.
DO NOT point the compressed air jet at persons.
DO NOT point the compressed air jet at loose objects.
CAUTION
Hearing damage caused by sound overexposure
Peak noise levels (for a short time up to 95 db(A)) occurring during
the cleaning process may cause hearing damage.
Do not approach the OptiCenter unless absolutely necessary!
Wear adequate hearing protection (e.g. ear muffs per EN 352-1)!
A great deal of air is required for the cleaning procedure!
Make sure that 6 bar is always available!
ATTENTION
Powder can escape if the OptiSpeeder cover is not closed
properly.
Check that the cover fits properly
Check that the lock is properly engaged. The lock tension has
been set at the factory and must not be changed under any
circumstances!
ATTENTION
Damage to the sieve mesh tension
When using an ultrasonic sieve**, the sieve mesh tension is
damaged during cleaning!
The OptiSpeeder must only be cleaned with the cover on
WITHOUT a US sieve.
Cleaning procedure (standard)
1. End the coating procedure
2. To exit Coating mode, press and hold the key for 2 seconds.
The following menu appears on the display:

Table of Contents