Rev. 00 03/19
OptiStar 4.0 (CG24-CP) Operation
41
Operation
Operation
During the initial commissioning of the device, the functional
check is to be performed without powder!
Select predefined operating mode (Preset mode)
1. Turn on the gun control unit with the ON key
2. Press the corresponding application key.
The arrow above the desired button lights up.
The pre-defined application modes have preset values for high
voltage and spray current:
Application mode
Preset kV
Preset µA
flat parts
100
100
complicated parts
100
22
overcoat
100
10
3. The air values for total air, powder output and electrode rinsing air
can be individually defined and are saved in the programs.