Rev. 00 03/19
44
Operation OptiStar 4.0 (CG24-CP)
Setting the spraying air
The spraying air (ZL) will be set in accordance to the calculated transport
air (TL) and the adjusted total air volume (GL).
Formula:
GL = ZL + TL
fig.
21
: Air streams in the diffuser adapter
GL
Total air
TL
Transport air
ZL
Spraying air
P
Gun
Setting the electrode rinsing air
1. Press the key.
The second display level will be shown.
2.
Adjust the correct electrode rinsing air according to the applied
nozzles (deflector plate, flat jet nozzle)
≈ 0.1 Nm³/h
≈ 0.5 Nm³/h
too much electrode rinsing air
3. If in this display level is no operation for 3 seconds, the first display
level is switched over independently.