Reference Manual
Prox–DU & Prox–SU
www.gemalto.com
DOC118569D Public Use Page 109/145
This command is only available when the boot-loader is running.
Refer to the “Boot-Loader” paragraph for more information.
End download command
This command is the last command of the download process.
This command is only available when the boot-loader is running.
Refer to the “Boot-Loader” paragraph for more information.
HID Library
A library is available for the following operating systems:
• Windows
• Linux
• Mac OS X
This library supports all the commands listed in the previous paragraph.
The HID libraries are available in the following web link http://support.gemalto.com
.
HID Commands Error Codes
In the following table:
• The MSB byte correspond to the first byte reported in the abStatus field of the HID
response
• The LSB byte correspond to the second byte reported in the abStatus field of the
HID response
Error label Value Meaning
ERR_OK 0000h Execution OK
Wrong command or wrong data parameters (command rejected)
ERR_BAD_COMMAND FF82h Wrong command bytes
ERR_BAD_PARAM FF83h Wrong data parameters
Other codes FFxxh not listed are RFU
Table 26 – Common error codes