Do you have a question about the General Monitors S5000 and is the answer not in the manual?
Sensor Type | Electrochemical |
---|---|
Gas Detected | Oxygen, Toxic and Combustible Gases |
Enclosure | Stainless Steel |
Certifications | ATEX, IECEx, UL, CSA |
Detection Principle | Electrochemical, Infrared |
Enclosure Rating | IP66 |
Power | 12-30 VDC |
Details the warranty periods for the S5000 Gas Monitor and its components.
Covers the S5000's Bluetooth communication capabilities, pairing, and range.
Details the TruCal technology for sensor verification and adaptive environmental compensation.
Presents critical safety warnings and precautions to follow before commencing installation.
Details various mounting options and considerations for the S5000 Gas Monitor.
Specifies the correct orientation for IR and digital sensors to prevent clogging and ensure proper function.
Explains the process of connecting sensors to the S5000 transmitter or junction box.
Guides on how to safely connect electrical power to the S5000 Gas Monitor.
Lists critical safety warnings and precautions before making any electrical connections.
Details power load requirements and provides tables for maximum mounting distances based on wire gauge.
Provides step-by-step instructions for connecting power and analog output wires.
Explains the electrical connections for the relay board and power for the S5000.
Details the initial startup sequence, sensor warm-up times, and behavior after power loss.
Explains how to navigate menus and change various instrument settings.
Covers configuring gas units, ranges, calibration levels, and alarm settings for sensors.
Covers configuring relay zone mapping and energized/de-energized states.
Shows how to check the remaining life and health status of XCell sensors.
Details calibration frequency for XCell sensors with TruCal, including conditions that may prompt calibration.
Provides step-by-step instructions for performing zero calibration on XCell and IR sensors.
Details the calibration procedure for an Oxygen XCell sensor.
Explains the calibration process for IR sensors, focusing on restoring zero response.
Provides instructions for calibrating passive sensors, including catalytic bead and MOS types.
Details the steps for cleaning the IR sensor windows to ensure performance.
Guides users through the process of replacing the XCell sensor, including safety precautions.
Explains how to identify and clear blockages in the sensor inlet and frit.
Details the procedure for replacing passive sensors like Catalytic Bead or MOS.
Provides a guide to identifying and resolving common faults and errors.