Class I, Division 1, Groups A, B, C, D; T5/T6*
Class I, Division 2, Groups A, B, C, D; T4/T6*
Class II, Division 1,2 Groups E, F, G; Class III, Division 1,2; T6 (T5 under FM Approval)
NOTE: See CSA Certificate for detailed certification information including possible
limitations to the above information. FM Approval does not include Zone classified locations.
*Applicable to S5000 Junction Box only
U.S. Zone Hazardous Locations as defined by the NEC
Class I, Zone 1, AEx db IIB+H2 T5/T6* Gb
Class I, Zone 2, AEx nA nC** IIC T4/T6* Gc
Zone 21, AEx tb IIIC T85°C Db
NOTE: See CSA Certificate for detailed certification information including possible
limitations to the above information. FM Approval does not include Zone classified locations.
*Applicable to S5000 Junction Box only
**nC not applicable to S5000 Junction Box
Canadian Division Hazardous Locations as defined by the CEC
Class I, Division 1, Groups A**, B, C, D; T5/T6*
Class I, Division 2, Groups A, B, C, D; T4/T6*
Class II, Division 1,2 Groups E, F, G; Class III, Division 1,2; T6
NOTE: See CSA Certificate for detailed certification information including possible
limitations to the above information.
*Applicable to S5000 Junction Box only
**Applicable for cemented window covers only
Canadian Zone Hazardous Locations as defined by the CEC
Ex db IIB+H2 T5/T6* Gb
Ex nA nC** IIC T4/T6* Gc
Ex tb IIIC T85°C Db
NOTE: See CSA Certificate for detailed certification information including possible
limitations to the above information. *Applicable to S5000 Junction Box only
**nC not applicable to S5000 Junction Box
ATEX/IECEx/INMETRO Hazardous Locations
(Sira 17ATEX1048X, Sira 17ATEX4052X, IECEx SIR 17.0016X, NCC 18.0097X)
Ex db IIB+H2 T5/T6* Gb
Ex nA nC** IIC T4/T6* Gc
Ex tb IIIC T85°C Db
NOTE: See ATEX/IECEx Certificates for detailed certification information including
possible limitations to the above information.
*Applicable to S5000 Junction Box only
**nC not applicable to S5000 Junction Box
NOTE: For configurations incorporating cemented covers, IIB+H2 is replaced by IIC.

Table of Contents

Other manuals for General Monitors S5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the General Monitors S5000 and is the answer not in the manual?

General Monitors S5000 Specifications

General IconGeneral
Sensor TypeElectrochemical
Gas DetectedOxygen, Toxic and Combustible Gases
EnclosureStainless Steel
CertificationsATEX, IECEx, UL, CSA
Detection PrincipleElectrochemical, Infrared
Enclosure RatingIP66
Power12-30 VDC