GlobalPowerTechnologies 2-5
5120
2) Pushtheignitorrodinasfarasitwillgo,(itshouldextendabout25mm(1in.)pastthe
holdingscrew),thenpullitback3mm(1/8in.).
3) Tightenthewing-nut,DONOTovertightenastheignitorrodwillcrack.
2.5.1 SI-SO Start
1) Turnonthefuelsupply.
2) Pushinthebuttonontopofshut-o󰀨valve.Thesparkignitorshouldbeginclickingand
thesoundofcombustionwillbegin.Insomecasesitmaybenecessarytobleedairfrom
thefuellinebeforecombustionwillbegin.
3) Continuetoholdthebuttondownforatleast90secondsaftercombustionbegins,then
release the button.
4) Ifthesoundofcombustionstops,pushthebuttonagainuntilcombustionissustained.
Note:Itisnecessarytofullydepressthebuttonbeforereleasingit.
2.5.2 Manual Start
IftheTEG’sSIsystemismalfunctioning,onecanmanuallystartthegenerator.Itshouldbe
notedthatthemalfunctioningSIberepairedassoonaspossibleastheTEGwillnotbeableto
reigniteitselfintheeventthattheTEG’sburnergoesoutbecauseoffuelinterruptions.
Figure 5WiringDiagram5120TEGwithnoLimiter/Converter