3.3 Troubleshooting Guide
Symptom
Probable Cause RemedyandProcedure
Burnerdoesnot
ignite.
Airinfuelline. Purgefuellines.
Gas supply pressure too low.
Minimumgassupplypressureis69
kPa(10psig).Section2.4.
Incorrectpressureregulator
setting.
Adjustpressure.Section2.6and2.6.5.
Dirtyfuellter.
Drainregulatorsedimentbowl.Section
3.2.2.1.
Replacefuellter.Section3.2.2.2.
Oriceplugged. Replaceorice.Section3.2.2.3.
Airadjustmentincorrect Adjustairsupply.Section2.6.4.
Cleanairscreen. Section3.2.3.
SIsystemnotworking. CheckSISystem.Section3.2.5.
Burnerwillignitebut
willnotcontinueto
burn.
Supply gas pressure to low.
Minimumsupplygaspressureis69
kPa(10psig).Section2.4.
Incorrectpressureregulator
setting.
Adjustpressure.Section2.6.5
Dirtyfuellter.
Drainregulatorsedimentbowl.Section
3.2.2.1.
Replacefuellter.Section3.2.2.2.
Oriceplugged. Replaceorice.Section3.2.2.3.
SOThermocouplenotwork-
ing.
Checkthermocouple.Section3.2.6.
SOValvenotworking. CheckSOValve.Section3.2.6.
Airadjustmentincorrect
Adjustairsupply.Section2.6.4.
Cleanairscreen.Section3.2.3