EasyManua.ls Logo

Global 5120 - 3.3 Troubleshooting Guide

Global 5120
79 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GlobalPowerTechnologies 3-12
5120
3.3 Troubleshooting Guide
Symptom
Probable Cause RemedyandProcedure
Burnerdoesnot
ignite.
Airinfuelline. Purgefuellines.
Gas supply pressure too low.
Minimumgassupplypressureis69
kPa(10psig).Section2.4.
Incorrectpressureregulator
setting.
Adjustpressure.Section2.6and2.6.5.
Dirtyfuellter.
Drainregulatorsedimentbowl.Section
3.2.2.1.
Replacefuellter.Section3.2.2.2.
Oriceplugged. Replaceorice.Section3.2.2.3.
Airadjustmentincorrect Adjustairsupply.Section2.6.4.
Cleanairscreen. Section3.2.3.
SIsystemnotworking. CheckSISystem.Section3.2.5.
Burnerwillignitebut
willnotcontinueto
burn.
Supply gas pressure to low.
Minimumsupplygaspressureis69
kPa(10psig).Section2.4.
Incorrectpressureregulator
setting.
Adjustpressure.Section2.6.5
Dirtyfuellter.
Drainregulatorsedimentbowl.Section
3.2.2.1.
Replacefuellter.Section3.2.2.2.
Oriceplugged. Replaceorice.Section3.2.2.3.
SOThermocouplenotwork-
ing.
Checkthermocouple.Section3.2.6.
SOValvenotworking. CheckSOValve.Section3.2.6.
Airadjustmentincorrect
Adjustairsupply.Section2.6.4.
Cleanairscreen.Section3.2.3

Table of Contents