GMC-I Messtechnik GmbH 3
Overview of the Scope of Functions of the SECUTEST
BASE(10), PRO and SECULIFE ST BASE(25) Test Instruments
1
10/25 A-R
PE
measurements are only possible with line voltages of 115/230 V and
line frequencies of 50/60 Hz.
2
Voltage measuring inputs with SECUTEST PRO or instrument with feature I01) and
SECULIFE ST BASE(25) only
3
Connection of 2
nd
test probe for two-pole measurement with SECUTEST PRO (or in-
strument with feature H01) and SECULIFE ST BASE(25) only
4
Measurement of time to trip is not possible in IT systems.
5
No checking for reversed polarity takes place when the EL1 adapter is used.
6
Type of connection not available with
SECULIFE ST BASE25
(feature G02)
Key
Alternative = alternative measurement (equivalent leakage
current measurement)
Differential = differential current measurement
Direct = direct measurement
LN(TS) = short-circuited L and N conductors at test socket
P1 = measurement with test probe P1
P1-P2 = 2-pole measurement with test probes P1 and P2
PE-P1 = measurement between PE and test probe P1
PE(TS) = protective conductor at the test socket
PE(mains) = protective conductor at the mains connection
Differences with Regard to Included Features
* For voltage measurement, or for connecting a current clamp sensor for current
measurement or an AT3 adapter, and for temperature measurement via RTD
Scope of Delivery
Standard Version (country-specific)
1 SECUTEST BASE(10)/PRO or SECULIFE ST BASE(25) test instrument
1 Mains power cable
1 Test probe, 2 m, not coiled
1 USB cable, USB A to USB B, 1.0 m long
1 Plug-on alligator clip
1 KS17-ONE cable set for voltage measuring input (only with
SECUTEST PRO
and
SECULIFE ST BASE(25)
or device with feature I01)
1 Calibration certificate
1 Condensed operating instructions
1
Comprehensive operating instructions available on the Internet
1Card with
registration key
for software
Switch
Position
Measuring Functions
Test Current/Voltage
Measurement
Type,
Connection Type
Single measurements, rotary switch level: green
R
PE
Section
8.5
R
PE
Protective conductor resistance
PE(TS) - P1 passive
PE(TS) - P1 active
PE(mains) - P1
6
PE(mains) - P1 clamp
2,
6
P1–P2
3
I
P
Test current (200 mA)
SECUTEST BASE10/PRO
and SECULIFE ST BASE 10 A
1
(feature G01)
and SECULIFE ST BASE25 25 A
1
(feature G02)
RISO
Section
8.6
R
INS
Insulation resistance (PC I/PC II)
LN(TS) - PE(TS)
LN(TS) - P1
P1–P2
3
PE(mains) - P1
PE(TS) - P1
LN(TS) - P1//PE(TS)
U
INS
Tes t voltage
IPE
Section
8.7.1
I
PE
Protective conductor current, RMS
Direct
Differential
Alternative
AT3-Adapter
2
Clamp
2
I
PE~
AC component
I
PE=
DC component
U
LPE
Tes t voltage
U
Gen
A reference voltage (alternative)
IB
Section
8.7.2
I
T
Touch current, RMS
Direct
Differential
Alternative (P1)
Permanent connection
Alternative (P1–P2)
I
T~
AC component
I
T=
DC component
U
LPE
Tes t voltage
U
Gen
Reference voltage (alternative)
IG
Section
8.7.3
I
E
Device leakage current, RMS
Direct
Differential
Alternative
AT3-Adapter
2
Clamp
2
I
E~
AC component
I
E=
DC component
U
LPE
Tes t voltage
U
Gen
Reference voltage (alternative)
IA
Section
8.7.4
I
A
Leakage current from the applied part, RMS
Direct (P1)
Alternative (P1)
Perm. con. (P1)
U
LPE
Tes t voltage
U
Gen
Reference voltage (alternative)
IP
Section
8.7.5
I
P
Patient leakage current, RMS
Direct (P1)
Perm. con. (P1)
I
P~
AC component
I
P=
DC component
U
LPE
Tes t voltage
U
Section
8.9
U
Probe voltage, RMS
P1–P2
P1–P2 (with mains *)
* Polarity parameter
U
~
Alternating voltage component
U
=
Direct voltage component
U Measuring voltage, RMS
2
V – COM
V – COM (with mains)
U
~
Alternating voltage component
2
U
=
Direct voltage component
2
ta
4
Section
8.10
ta PRCD time to trip
for 10/30 mA PRCDs
U
LN
Line voltage at the test socket
P
Section
8.11
Function test at the test socket
Polarity parameter
I Current between L and N
U Voltage between L and N
f Frequency
P Active power
S Apparent power
PF Power factor
Probe measuring functions
EL1
Section
8.12
Extension cord with adapter:
continuity, short-circuit, polarity (wire reversal
5
)
EL1 adapter
AT3-IIIE adapter
VL2E adapter
EXTRA
Section 9
Reserved for expansion within the framework of software updates
°C
Temperature measurement
2
with Pt100 / Pt1000
V – COM
IZ Current clamp measurement
2
with the current clamp sensor
V – COM
Switch
Position
Standard Measurement Type, Connection Type
Automated test sequences, rotary switch level: orange
Preconfigured (freely adjustable) test sequences – default settings
A1
VDE 0701-0702 Passive measurement type, test socket
A2
VDE 0701-0702 Active measurement type, test socket
A3
VDE 0701-0702-EDV
Parameters configuration for EDP (active)
A4
IEC 62353 (VDE 0751) Passive measurement type
A5
IEC 62353 (VDE 0751) Active measurement type
A6
IEC 60974-4 Connection type: test socket
A7
IEC 60974-4 Connection type: AT16-DI/AT32-DI
A8
VDE 0701-0702
Extension cord measurement type (RPE, RINS), adapter:
EL1
/VL2E/
AT3-IIIE
AUTO
VDE 0701-0702 Active measurement type, test socket
SECUTEST...
Features
BASE PRO PRO BT
comfort
—
SECULIFE... — ST BASE —
ST BASE 25
Touchscreen / keyboard E01 •••
10 A RPE test current
G01
••
25 A RPE test current
G02
•
2
nd
test probe H01 •••
Voltage measuring input *
I01 •••
SECUTEST DB+
KB01 •••
SECUTEST DB COMFORT
KD01 ••
Bluetooth
®
M01 •
Antimicrobial housing
— ST BASE •