Integration
333587B 79
A Drum Sizes
Enum Number:
0: 20 Liters
1: 200 Liters
B Heat Idle Timeout xx hours
C Line Voltage, Leg #1 xxx Volts
D Line Voltage, Leg #2 xxx Volts
E Line Voltage, Leg #3 xxx Volts
x000 AMZ Active Zone #x Alarms Bitfield
x001 AMZ Active Zone #x Deviations Bitfield
x002 AMZ Active Zone #x Advisories Bitfield
x003 Zone #x Heat State
Bit Number:
0: Heat Zone Off
1: Heat Zone On
2. Heat Zone Warming up
3. Heat Zone At Temperature
4. Heat Zone is Heat Soaking
5. Heat Zone is in Setback
6. Heat Zone has an Error
x004 Zone #x Actual Temperature xx deg C
x005 Zone #x Actual Current Usage xx.xxx A
x006 Zone #x Actual Duty Cycle xxx.xx %
x007 Zone #x Soak Time Reminding xx seconds
x008 Zone #x Setpoint Temperature xx deg C
x009 Zone #x Setback Temperature xx deg C
x00A Zone #x Heat Soak Time xx minutes
x00B Zone #x Heat Enabled/ Installed State boolean
x00C Zone #x OtherTandem Heat Enabled/Installed State boolean
x00D Zone #x Type State
Enum Number:
0: Hose
1: Valve
2: Manifold
3: PGM
4: Flowmeter
5: Press Regulator
6: Other
7: Pump
8: Platen