Cleanup
18 3A3393C Operation
Cleanup
1. Perform Pressure Relief Procedure, page 9.
2. Remove guard and SwitchTip from all guns.
3. Unscrew cap(s), remove filter(s). Assemble without
filter.
4. Clean filter, guard and SwitchTip in flushing fluid.
5. Place siphon tube set in grounded metal pail par-
tially filled with flushing fluid. Attach ground wire to
true earth ground. Perform Startup steps 11 - 17
(see page 11) to flush out paint in sprayer. Use
water to flush water-base paint and mineral spirits
solvent (also called white spirit) to flush oil-base
paint.
6. Hold gun against paint bucket and pull trigger until
water or solvent appears.
7. Move gun to solvent or water bucket. Hold gun
against bucket and pull trigger until the system is
thoroughly flushed.
8. Fill pump with Pump Armor and reassemble filter,
guard and SwitchTip.
9. Each time you spray and store, fill throat packing
nut with TSL to decrease packing wear.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury
from pressurized fluid, such as skin injection, splash-
ing fluid and moving parts, follow the Pressure Relief
Procedure when you stop dispensing and before
cleaning, checking, or servicing the equipment.
TI3371A
ti6269a
FLUSH
TI3375A
ti3322b

Other manuals for Graco LineLazer V250SPS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco LineLazer V250SPS and is the answer not in the manual?

Graco LineLazer V250SPS Specifications

General IconGeneral
BrandGraco
ModelLineLazer V250SPS
CategoryConstruction Equipment
LanguageEnglish

Related product manuals