Repair
3A0420V 43
Hoppers
1. If material is in the hopper pump out the remaining
material.
2. If the pump has failed:
a. Place a waste container beneath the plug on fit-
ting (61). Remove the plug.
b. Drain all material from hopper into the waste
container.
c. Install plug after material is no longer draining
from fitting (61).
3. Follow Pressure Relief Procedure, page 24.
4. Loosen fitting (61) and disconnect hopper from
pump.
5. Remove the recirculation line from the hopper and
place in a waste container.
6. Lift the hopper off of the mounting bracket.
7. Repeat for second hopper.
Optional Solvent Pump
1. Follow Pressure Relief Procedure, page 24.
2. Disconnect the fluid line and air lines from the sol-
vent pump.
3. Loosen the four screws that attach the solvent pump
to the cart (1). Lift and pull pump from the slots.
4. Refer to the Merkur Pump Assembly manual to ser-
vice or repair the solvent pump.
5. Follow the steps in reverse order to reinstall the sol-
vent pump.
plug
61
r_571101_3a0420a_41a
U
r_571101_3a0420a_18a
screw
1

Table of Contents

Other manuals for Graco XP70

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco XP70 and is the answer not in the manual?

Graco XP70 Specifications

General IconGeneral
Fluid Output2.0 gpm (7.6 lpm)
Fluid Delivery2.0 gpm (7.6 lpm)
Maximum Fluid Working Pressure7250 psi (500 bar)
Maximum Air Input Pressure100 psi (7 bar)
Fluid Outlet Size3/8 in npsm(m)
Wetted PartsStainless Steel, PTFE, UHMWPE
Maximum Pressure7250 psi (500 bar, 50 MPa)
Hose Length50 ft