Repair
44 3A0420V
Optional Fluid Heaters
NOTE: Wiring for heaters is not provided. See the Vis-
con HP heater manual for wiring, repair, and parts infor-
mation for explosion-proof heaters.
Service and Repair
1. Follow Pressure Relief Procedure, page 24.
2. Disconnect the fluid lines and electrical wiring from
the fluid heater.
3. Refer to the Viscon HP heater manual to service or
repair. Refer to the heater adapter kit manual
406861 for installation instructions.
4. Reconnect the fluid lines and electrical wiring.
Replace
1. Follow steps 1 through 2 in the Fluid Heaters Ser-
vice and Repair section.
2. Loosen the four mounting screws, lock washers,
and plain washers on back of the heater. Slide the
heater up and remove from the cart.
3. Replace the heater. Follow the steps in reverse
order to install a new heater.