15-6
Error Messages in GP-GL Command Mode
Error
Displayed
LCD Display Cause Solution
E02001 The plotter received an unrecognizable
command.
Press the [ENTER] key.
Noise came in when the computer was
turned on.
Congure to drive the plotter from the menu
of the software.
The software conguration regarding the
output device has been changed.
Reset the interface settings of the software.
The plotter's interface conditions have
changed.
Reset the interface settings of the plotter.
E02004 A command was received containing
numeric parameters that exceed that
command's permissible range.
Congure to drive the plotter from the menu
of the software.
The software conguration regarding the
output device has been changed.
Reset the interface settings of the software.
The plotter's interface conditions have
changed.
Reset the interface settings of the plotter.
E02005 An error occurred in the receipt of data
within the interface.
Congure to drive the plotter from the menu
of the software.
The software conguration regarding the
output device has been changed.
Reset the interface settings of the software.
The plotter's interface conditions have
changed.
Reset the interface settings of the plotter.
E02006 The data out of cutting range has been
received.
Check the data.
Check the size of media and the cutting
range.
Check the magnication setting.
Check the step size settings.