Options: FC5100 Auto Registration Mark Sensor
187
mark sensor. The plotter plots the second cross mark based
on the reading of the first cross mark then adjusts for offset.
Note: To avoid confusion, plot using different color pens between the first and second
cross marks.
Load the media and set the pen in the plotter.
If you wish to use METHOD 1,
you must load media with a printed cross mark.
Press the MENU key to select MENU mode
Press the NEXT key
Press the F1 key to select AUTO REG. MARK
Press the F4 key to select SENSOR OFFSET ADJ
Press the F3 or F4 key to select METHOD 1 or METHOD 2
Select either METHOD 1 or METHOD 2
SELECTING METHOD 1
The plotter scans a printed cross mark and then plots a second cross mark
based on the reading of the printed cross mark. The plotter then adjusts for offset.
Press the POSITION key to move the pen near to the pre-printed cross mark.
AUTO REG. MARK>*
PEN UP/DOWN>*
BUFFER CLEAR>*
FEED>*
MARK SCAN MODE>*
MARK TYPE>*
OTHER SETUPS>*
SENSOR OFFSET ADJ>*
SENSOR OFFSET ADJUST
METHOD 1>.
METHOD 2>.