FC9000-UM-251-9370 7-15
7 DISASSEMBLY AND REASSEMBLY
(6) Remove the two M2L3 binding head screws holding the solenoid, and then detach it from the
registration mark sensor unit.
M2L3 binding head screw
(7) Remove the two C2L5 self-tapping screws holding the registration mark sensor, and then detach it from
the registration mark sensor unit.
Registration mark sensor
C2L5 self tapping screw
(8) Disconnect the registration mark sensor cable from the registration mark sensor.
Registration mark sensor
Registration mark sensor
Registration mark sensor cable
How to reinstall the registration mark sensor
(1) Reattach the registration mark sensor in the reverse order in which it was detached.
(2) When the registration mark sensor unit is installing to the pen block, conrm the cables of registration
mark sensor unit are not pinched by the registration mark sensor unit.
Conrm the cables are not
pinched by the registration
mark sensor unit at this part.
(3)
Perform the registration mark sensor sensitivity adjustment (Refer to subsection 8.13.).
(4) Perform the registration mark sensor offset adjustment (Refer to subsection 8.14.2.).