FC9000-UM-251-9370 7-36
7 DISASSEMBLY AND REASSEMBLY
7.2.16 Replacing the Y Flexible Cable
How to detach the Y Flexible Cable
(1) Detach the right side cover (Refer to subsection 7.1.1.).
(2) Detach the control panel assembly (Refer to subsection 7.1.3.).
(3) Detach the center cover (Refer to subsection 7.1.4.).
(4) Release the cable ties holding the Y exible cable.
Main board
Y exible cable
Cable tie
(5) Disconnect the Y exible cable from the main board.
(6) Remove M3L4 binding head screw holding the cable tie on Y slider, and then detach it.
Y relay board
Cable tie
Y exible cable
M3L4 binding head screw
(7) Disconnect the Y exible cable from the Y relay board.
(8) Peel off the Y exible cable from the Y exible cable guide.