FC9000-UM-251-9370 8-8
8 Electrical Adjustment
8.4 Explanation of the Values of the Main Board Settings
The default factory adjustment values are recorded on label in the location shown below.
When the SUB-NVRAM of adjustment values are not able to copy to the main board, use this values.
If you have changed any values by making adjustments, record those values for the next maintenance check.
PEN FORCE DISTANCE
10 48 130 210 515 618 X Y Z
xx xx xxx xxx xxx xxx xxx.xx xxx.xx xxx.xx
RMS C-CUT PENSEL 1-2TOOL MEDIA SENS
X Y Y Y H X Y F R
xx.xx xx.xx xx.xx xx.xx xx.xx xx.xx xx.xx xx.xx xx.xx
Explanation of the values
• PEN FORCE Pen force adjustment values for each target force.
• DISTANCE X and Y for the distance adjustment value, Z for the diagonal distance value
used to the right angle adjustment.
• RMS X and Y for the offset adjustment value of the registration mark sensor
position.
• C-CUT Cross cutter position adjustment value.
• PENSEL Pen exchange position adjustment value (This is recorded when the option 2
pen kit was installing.).
• 1-2TOOL 1 - 2 Tool spacing adjustment value (This is recorded when the option 2 pen
kit was installing.).
• MEDIA SENS Front and rear media sensor position adjustment values.