Slicer/Applicator
SS-10.DOC:1/26/2007 11:08 AM
Grote Company
41
Chart 5: Product Slinging
Chart 6: Product Curling Or Twisting
Proper Amount of
Water
Product Temperature
Product Slinging
Product Curling Or Twisting
Product Temperature
Product Holder Height
Product Transfer
Fingers Bent,
Jammed Or Missing.
Insure that product is within proper slicing range.
Check transfer fingers for excess product build-
up.
Clean, straighten or replace.
Blade Not Tracking
Correctly
Improper Blade Guide
(Non Water-
Injected Blade Guide Machines) Refill water
res
ervoir. Check water applicator pad for product
residue. Adjust control valve or timer.
The colder the product the more severe the curl. The
warmer the more severe the twisting. Is the product
temperature in the proper slicing range?
Check blade and guide for product residue. Check water
reservoir and
water applicator pad if provided. Retrack
according to manual (See Page 29).
Do you have the correct style blade guide for what you are
trying to accomplish? Contact Grote Service Department at
1-888-JEGROTE, Monday - Friday 8am - 5pm.
Slice Gap Not Set
Correctly
Reset slice gap according to chart in manual (See Page
26
).
Thickness Tray Not
Set To Proper Range
Proper range starts at ground zero and must be
releveled at 1/4 inch increments according to
slice
thickness.
No less then 1/32 no more then 1/16 from trailing edge
of product holder to the blade (See Page 19).