EasyManua.ls Logo

Grundfos DDI 222 - User Manual

Grundfos DDI 222
632 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DDI 222
Dosing pump
Installation and operating instructions
GRUNDFOS INSTRUCTIONS
Further languages
http://net.grundfos.com/qr/i/96690281

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Grundfos DDI 222 and is the answer not in the manual?

Grundfos DDI 222 Specifications

General IconGeneral
BrandGrundfos
ModelDDI 222
CategoryWater Pump
LanguageEnglish

Summary

General Information

Introduction

Overview of the DDI 222 dosing pump and manual.

Service Documentation

Guidance on contacting Grundfos for service or additional information.

Information about the Product

Details on DDI 222 pump types (1.3.1), connection sizes (1.3.2), performance (1.3.3), accuracy (1.3.4), pressure/suction lift (1.3.5), sound pressure (1.3.6), enclosure class (1.3.7), and energy (1.3.8).

Ambient and Operating Conditions

Specifies ambient temperature, humidity, and permissible media conditions.

Dosing Medium

Basic characteristics and viscosity limits for dosing media.

Applications

Defines appropriate, acceptable, and correct usage of the DDI 222 pump.

Safety

Identification of Safety Instructions

Explains symbols used for safety instructions in the manual.

Qualification and Training of Personnel

Specifies requirements for personnel operating, maintaining, or installing the pump.

Risks when Safety Instructions are Not Observed

Outlines potential hazards from non-compliance with safety instructions.

Safety-Conscious Working

Emphasizes adherence to safety instructions and regulations.

Safety Instructions for the Operator;User

Specific safety advice for pump operators and users.

Safety Instructions for Maintenance, Inspection and Installation Work

Safety guidelines for carrying out maintenance, inspection, and installation.

Unauthorised Modification and Manufacture of Spare Parts

Rules regarding pump modifications and use of spare parts.

Improper Operating Methods

Highlights risks associated with operating the pump incorrectly.

Safety of the System in the Event of a Failure in the Dosing System

Guidelines for designing systems to ensure safety during pump failure.

Transport and Intermediate Storage

Transport

Instructions on how to handle the pump during transport.

Delivery

Information about the pump's packaging upon delivery.

Unpacking

Guidance on unpacking the pump and retaining packaging.

Intermediate Storage

Conditions for storing the pump between transport and installation.

Return

Procedures for returning the pump for service or storage.

Technical Data

Identification

Explains the pump nameplate and its components.

Type Key

Details the coding system used to define pump specifications and variants.

General Description

Provides a general overview of the DDI 222 pump's EC motor and control unit.

Safety Functions

Overview of pump safety features like diaphragm leakage detection and pressure control.

Diaphragm Leakage Detection (Optional)

Explains the optional diaphragm leakage sensor and its function.

Pressure Control

Describes the pump's pressure control feature and system protection.

Dosing Control (Flow Monitor)

Details the Flow Monitor option for dosing control and pressure monitoring.

Flow Compensation

Explains the flow compensation function for maintaining constant dosing flow.

Dimensional Sketches

Provides diagrams with dimensions for various DDI 222 pump models.

Weight

Lists the weights of different DDI 222 pump types and dosing head materials.

Materials

Specifies the materials used for pump housing, sensor, and pressure switch.

Control Unit

Outlines the functions and operating modes of the DDI 222 control unit.

Installation

General Information on Installation

General warnings and specifications for pump installation.

Installation Location

Guidelines for selecting a suitable installation site for the pump, including ambient influences, mounting surface, and space requirements.

Mounting

Instructions on how to physically mount the pump.

Space Required for Operation and Maintenance

Specifies the necessary space around the pump for access and servicing.

Installation Examples

Illustrates typical pump installation configurations with component labels.

Installation Tips

Provides practical advice for installing suction and discharge lines, and related components.

Sizing of Tube; Pipe Lines

Guidelines for selecting appropriate tube and pipe sizes for the pump.

Connecting the Suction and Discharge Lines

Instructions on how to properly connect the suction and discharge lines.

Electrical Connections

Connecting the Signal Lines for DDI 222

Details on connecting signal lines for diaphragm leakage and pressure sensors.

Diaphragm Leakage Signal; (Pressure Sensor - Flow Monitor)

Wiring instructions for diaphragm leakage and pressure sensor signals to socket 1.

Current Output; Flow Monitor (Pressure Sensor)

Wiring details for pressure sensor and current output signals to socket 2.

Stroke;Pulse Signal; Pre-Empty Signal; Error Signal

Instructions for connecting stroke/pulse, pre-empty, and error signals to socket 3.

Remote On;Off; Contact Input; Current Input

Wiring for remote on/off, contact, and current inputs to socket 4.

Empty Signal Only; Pre-Empty and Empty Signal

Instructions for connecting empty and pre-empty signals to socket 5.

PROFIBUS (Optional)

Information on connecting the PROFIBUS interface to socket 6.

Connecting the Power Supply Cable

Guidelines for safely connecting the pump's power supply cable.

Start-up;Shutdown

Initial Start-up; Subsequent Start-up

Checks and procedures for the initial and subsequent pump start-ups.

Assisting Suction for Systems Without Flooded Suction

Method to prime the pump when flooded suction is not possible.

Starting the Pump

Steps to start the pump and run it in continuous operation.

Tightening Dosing Head Screws

Procedure for tightening dosing head screws after initial start-up.

Operating the Pump

References to other sections for pump operation.

Shutdown

Steps for safely switching off and uninstalling the pump.

Operation

Control and Display Elements

Overview of the pump's control panel, buttons, and display indicators.

Display Test

Description of the automatic display test performed on pump power-up.

Display Indicator

Explanation of what is shown on the pump's display during operation.

Switching On;Off

Basic instructions for turning the pump on and off.

How to Use the Control Unit

Menu Levels

Explanation of the different menu levels for pump settings and functions.

General Functions of the Control Unit

Describes general functions like suction and locking the pump.

Two-Stage Tank-Empty Signal

How to configure and use tank-empty signals for pump control.

Diaphragm Leakage Sensor (MBS)

How the MBS sensor is detected and indicated on the display.

Blocking Safety

Describes the motor monitoring function for detecting blocked drives.

Power Off

Explains the power monitoring function and automatic restart attempts.

Remote On;Off

How to control the pump remotely using the on/off function.

Memory Function

Details the pump's memory function for storing contact signals.

Flow Monitor

Information on the pressure sensor option for dosing control.

Signal Outputs

Explains the available signal outputs for external monitoring.

Current Signal Output

How the pump's current flow rate is output as a current signal.

Error Signal

Function of the error signal output for returning error states.

Stroke Signal; Pre-Empty Signal; Pulse Input

How to configure relay outputs for stroke, pre-empty, or pulse signals.

First Function Level

Visual guide to navigating and setting parameters in the first function level.

Setting the Operating Modes

How to select and set operating modes (Manual, Contact, Analog) in the first function level.

Manual Control

Operating the pump in manual mode with adjustable flow rate.

Contact Signal Control

Using external contact signals to control dosing quantity and flow.

Current Signal Control 0-20 mA; 4-20 mA

How to control the pump using 0-20 mA or 4-20 mA current signals.

Setting the Access Code

Procedure for setting an access code to protect pump settings.

Second Function Level

How to navigate and modify settings in the second function level.

Calibration

Procedure for calibrating the pump flow rate to match operating conditions.

Weighting of Current Input;Output

How to adjust current signal input/output weighting for accurate dosing.

Batch Menu; Batch Mode

Setting and performing batch dosing operations manually or via contact.

Timer Menu; Timer Mode

Setting up timer-based batch dosing with defined start and repetition times.

PROFIBUS Menu

Menu for configuring the PROFIBUS interface and bus address.

Slow Mode

Adjusting pump flow rate in stages to reduce cavitation or for viscous media.

Display;Resetting of Total Dosing Capacity

How to view and reset the total accumulated dosing capacity.

Display of Total Number of Operating Hours

How to view the pump's total operating hours for maintenance tracking.

Service Level

How to access and configure service level settings.

Modifying the Switch Assignment

How to change switch assignments for electronics and pump settings.

Opening; Exiting the Service Level

Step-by-step guide to access and exit the service level menu.

Relay function (stroke; pre-empty; pulse selection)

Configuring relay functions for stroke, pre-empty, or pulse signals.

Relay output, NO;NC (stroke; pre-empty; pulse)

Setting relay output contacts as normally open (NO) or normally closed (NC).

Pre-empty signal, NO;NC input

Configuring pre-empty signal inputs as NO or NC.

Empty signal, NO;NC input

Configuring empty signal inputs as NO or NC.

Error signal, NO;NC output

Configuring error signal outputs as NO or NC.

Remote off, NO;NC input

Configuring remote off inputs as NO or NC.

Locking run on;off

Enabling or disabling the locking of the Start/Stop button.

P: CAL on;off (only for Flow Monitor)

Enabling or disabling pressure sensor calibration for Flow Monitor.

St: e.g. 60 (only for Flow Monitor)

Setting permissible error strokes during start-up for Flow Monitor.

FE: e.g. 7 (only for Flow Monitor)

Setting permissible error strokes during operation for Flow Monitor.

Selection of Unit (display)

Changing the display unit for dosing flow between l/h and gph.

Pump Selection

Selecting the correct pump type for accurate electronic function.

Resetting to Default Settings

Procedure to reset first and second function levels to default settings.

Current Signal Control 0-20 mA; 4-20 mA

How to control the pump using external 0-20 mA or 4-20 mA current signals.

Direct Weighting of the Current Signal Input and Output

How to set current input/output weighting directly in the first function level.

Current Input and Current Output with Subsequent Weighting

How to perform subsequent weighting or shift weighting in the second function level.

With Calibrated Pump

Steps for calibrating the pump and setting current weighting with a calibrated pump.

Setting the Weighting

Detailed procedure for setting current input/output weighting parameters.

Flow Monitor

Information on the pressure sensor option for dosing control.

Application Notes

Notes on using Flow Monitor with degassing media and viscous media.

Setting the Flow Monitor

Steps to switch on and set the dosing controller and pressure control functions.

Set Cut-off Pressure

How to set the pump's cut-off pressure to prevent overpressure.

Dosing Controller Function

How the pump software monitors dosing strokes and signals errors.

Pressure Control Function

How the pressure control function works and handles overpressure errors.

Pump Restart Attempts

Details on how the pump attempts to restart after a pressure-related stop.

Displaying the Pressure That Has Been Measured

How to view the currently measured pressure in the dosing head.

Error Message - Broken Cable or Faulty Sensor

How to identify and resolve errors related to broken cables or faulty sensors.

Changing the Number of Permissible Error Strokes

How to adjust the number of error strokes allowed before triggering an error.

Calibrating the Sensor After the Sensor Has Been Replaced

Step-by-step guide to calibrate the pressure sensor after replacement.

Batch Menu; Batch Mode

Setting Batch Dosing

How to set the desired dosing rate and batch quantity for batch operations.

Performing Batch Dosing

How to start and manage batch dosing manually or via contact.

Enabling Batch Mode

How to enable manual or contact batch dosing modes.

Timer Menu; Timer Mode

Setting Timer Mode

Setting up timer-based dosing cycles with defined quantities and timings.

Creating a Master;Slave Application

Master

How to configure the master pump for controlling slave pumps.

Slave

Information for slave pumps regarding operating modes and signal processing.

Hotkeys; Info Keys

Service Functions

Quick access to pump functions like suction, boot, and capacity deletion.

Display Functions in Batch and Timer Operation

Accessing batch and timer-related display information.

Other Display Functions

Accessing total dosing capacity, input current, and pressure displays.

Pump Safety Functions

Power Off

Details the 'Power Off' safety function, its indicators, and error behavior.

Blocking Safety

Details the 'Blocking Safety' function, its indicators, and error behavior.

Pressure Control (can be switched on and off)

Details the 'Pressure Control' safety function, its indicators, and error behavior.

Diaphragm Leakage Detection (optional)

Details the 'Diaphragm Leakage Detection' safety function, its indicators, and error behavior.

Maintenance

General Notes

General safety precautions and notes for maintenance.

Maintenance Intervals

Recommended intervals for performing maintenance tasks.

Cleaning

How to clean pump surfaces and components.

Cleaning the Valves and Diaphragm

Procedures for cleaning or replacing pump valves and diaphragms.

Cleaning Suction and Discharge Valves

Step-by-step guide for cleaning suction and discharge valves.

Resetting the Diaphragm

How to reset the diaphragm to its back dead point.

Diaphragm Breakage

Information on diaphragm leaks, potential dangers, and initial actions.

Replacing the Diaphragm

Detailed instructions for replacing the pump's diaphragm.

Dosing Liquid in the Pump Housing

Actions to take if dosing liquid enters the pump housing.

Repair

Guidance on sending the pump for repair and necessary documentation.

Fault Finding Chart

Disposal

Safety Declaration

Declaration of Conformity

Declaration of Conformity (Continued)

Declaration of Conformity EAC

Declaration of Conformity EAC (Continued)

Grundfos companies

Related product manuals