13
6.12 Wireless remote control
For wireless operation and reading of data, use the
GRUNDFOS remote control R100.
For application of the remote control, see section
7.3 R100.
7. Setting the pump
For the setting of the pump, use:
• Control panel.
• R100 remote control.
• Bus communication (not described in detail in
these instructions. Contact GRUNDFOS).
The following table shows the application of the indi-
vidual operating units and in which section the func-
tion has been described.
“-” = not available with this operating unit.
7.1 Factory settings
7.2 Control panel
The control panel, fig. 11, incorporates the following:
• Buttons, “+” and “–”, for setting.
• Light fields, yellow, for indication of control mode
and pump head.
• Indicator lights, green and red, for operating and
fault indication, see section 6.6 Indicator lights.
Fig. 11
7.2.1 Setting of control mode
Description of function, see section 6.1 Control
modes.
When the buttons “+” and “–” are pressed simultane-
ously, the light fields will indicate the selected control
mode:
If the buttons are pressed for more than 5 sec., the
control mode will change over to constant pressure
and proportional pressure respectively. This means
that constant curve duty is deactivated if selected by
means of the R100.
Function
Control
panel
R100
Proportional-pressure con-
trol
7.2.1 7.6.1
Constant-pressure control 7.2.1 7.6.1
Setting of pump head 7.2.2 7.4.1
Max. curve duty 7.2.3 7.4.2
Min. curve duty 7.2.4 7.4.2
Constant curve duty - 7.4.2
Temperature influence - 7.6.3
Resetting of fault indica-
tions
7.2.6 7.4.3
Activation/deactivation of
pump buttons
- 7.6.4
Allocation of pump number - 7.6.5
Reading of various data -
7.5.1 -
7.5.7
Start/stop 7.2.5 7.4.2
UPE xx-60 UPE xx-120
Control mode
Proportional
pressure
Proportional
pressure
Head
3 m at maximum
flow, see fig. 13
6 m at maximum
flow, see fig. 15
At high liquid temperatures, the pump may
be so hot that only the buttons should be
touched to avoid burns.
Light Fields Control mode
Top + bottom
light fields flashing
Proportional pressure
Middle light fields
flashing
Constant pressure
None of the light
fields are on
Constant curve
Buttons
Indicator lights
Light fields
TM00 4431 4596