What does P___ Invld Mode! mean on GSE Scales?
- AAriel HowardSep 22, 2025
The 'P___ Invld Mode!' error on GSE Scales means to key in a valid > > parameter and press, or press only or to proceed to the nearest lower valid parameter.
What does P___ Invld Mode! mean on GSE Scales?
The 'P___ Invld Mode!' error on GSE Scales means to key in a valid > > parameter and press, or press only or to proceed to the nearest lower valid parameter.
What does No Start mean on GSE Scales?
The 'No Start' error on GSE Scales indicates that a serial or A/D database collection command (%’ or %*) was executed prior to the “start collection” command.
What does CoDE14 Must Keyin mean on GSE Scales?
The 'CoDE14 Must Keyin' error on GSE Scales means that the choice for the current parameter must be keyed in.
What causes 'Entry >Max!' error on GSE 675 Scales?
The 'Entry >Max!' error on your GSE Scales is most likely caused by making an entry for an ID that is longer than the programmed size of that ID.
What does 'Outof Range' mean on GSE 675?
The 'Outof Range' message on your GSE Scales indicates that an entry made for a selection was beyond the range of valid choices.
What to do if my GSE 675 Scales display '#> Dsply'?
If your GSE Scales display '#> Dsply', either clear the totals or settle for only being able to transmit the totals.
Why do my GSE 675 display 'CoDE03 Over- Load!'?
The 'CoDE03 Over- Load!' error on your GSE Scales indicates that the input signal is greater than the positive full scale. Check for issues similar to those you would investigate for an underload situation.
What to do if my GSE 675 Scales show 'CoDE08 Check Conn'?
The 'CoDE08 Check Conn' error on your GSE Scales means the signal into the A/D is significantly greater than expected. This usually points to a defective or incorrectly wired load cell.
What does CoDE99 Can't Set! mean on GSE Scales?
The 'CoDE99 Can't Set!' error on GSE Scales indicates an attempt to enter a value for a parameter which is not field changeable, such as the serial numbers or the audit trail counter.
What does Wrong parm mean on GSE Scales?
The 'Wrong parm' error on GSE Scales means that the parameter specified for data collection using the %* command was invalid or not of type float.
Details the structure and purpose of the user manual.
Explains the formatting used for keystrokes and displayed messages.
Defines signal words and symbols for hazards and important notes.
Guidelines for connecting pluggable equipment to accessible sockets.
Specifies isolator requirements for permanently wired connections.
Instructions for safe handling and replacement of batteries to prevent explosion.
Advises against installing the unit near water as it is not a washdown unit.
Details DB9 connector pin assignments for connecting a remote scale.
Instructions for enabling and setting up the Quick Count application.
Details how to store and recall part numbers with average piece weight.
Explains how to access setup menus for the APW Lookup application.
Instructions for using the Quick Count method for parts counting.
Steps for sampling and counting parts using the APW Lookup.
Using the keypad for simple sample and count operations.
Important considerations and tips for performing calibration.
How to enter the calibration mode from the application menus.
Specific steps to access calibration from APW Lookup or Quick Count.
Introduction to the various calibration methods available.
Descriptions and remedies for operational errors like Under Load and Zero Max.