EasyManuals Logo

GW Instek GPT-12004 User Manual

GW Instek GPT-12004
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #233 background imageLoading...
Page #233 background image
REMOTE CONTROL
233
MANU:DCW:GROundmode
Set
Query
Description
Sets or returns the DCW Ground Mode. The test
must first be in DCW mode before this command
can be used.
Syntax
Query Syntax
MANU:DCW:GROundmode {ON|OFF}
MANU:DCW:GROundmode?
Parameter/
Return parameter
ON
DCW Ground Mode ON
OFF
DCW Ground Mode OFF
Example
MANU:DCW:GRO OFF
Sets the DCW Ground Mode off.
MANU:DCW:MAXHold
Set
Query
Description
Sets or returns the DCW MAX Hold. The test must
first be in DCW mode before this command can be
used.
Syntax
Query Syntax
MANU:DCW:MAXHold {ON|OFF}
MANU:DCW:MAXHold?
Parameter/
Return parameter
ON
DCW MAX Hold ON
OFF
DCW MAX Hold OFF
Example
MANU:DCW:MAXH OFF
Sets the DCW MAX Hold off.
MANU:DCW:PASShold
Set
Query
Description
Sets or returns the duration of DCW PASS Hold.
The test must first be in DCW mode before this
command can be used.
Syntax
Query Syntax
MANU:DCW:PASShold {<NR2>|ON}
MANU:DCW:PASShold?
Parameter/
Return parameter
<NR2>
0 ~ 999.9 seconds
ON
Indefinite duration

Table of Contents

Other manuals for GW Instek GPT-12004

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek GPT-12004 and is the answer not in the manual?

GW Instek GPT-12004 Specifications

General IconGeneral
BrandGW Instek
ModelGPT-12004
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals