PSU Series User Manual
110
2 = Control by external resistor -
rising
3 = Control by external resistor-
falling
4 = Control by isolated board
Output Status
when Power-ON
Output
Sets the power supply to turn the output on or off
at power up.
F-92
0 = Safe Mode (Always OFF),
1 = Force Mode (Always ON),
2 = Auto Mode (Status before last
time Power OFF)
Master/Slave
Configuration
Sets the power supply as master or slave. See the
parallel/series operation for details, page 67.
F-93
0 = Independent
1 = Master with 1 slave in parallel
2 = Master with 2 slaves in
parallel
3 = Master with 3 slaves in
parallel
4 = Slave (parallel)
External Output
Logic
Sets the external logic as active high or low for
analog control pin 19.
F-94
0= High ON, 1 = Low ON
Monitor Voltage
Select
Selects the voltage monitor output range.
F-96
0 = 5V, 1 = 10V
Control Range
Selects the external control range for external
voltage or resistance control.
F-97
0 = 5V [5k], 1 = 10V [10k]
External Output
Control Function
Set external output control on or off.
F-98
0 = OFF, 1 = ON